جزئیات آسیبپذیری
CVE-2026-34021
Wertheim SafeController 5400 Hardware for VAULT ROOMS
Lack of cryptographic protection in Wertheim SafeController 5400 enables RS-485 message sniffing and replay
CVSS 4.0
8.6بالا
شرح رسمی (انگلیسی)
The Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320, uses RS-485 communication between the server and the microcontroller without cryptographic protection. An attacker with access to the communication path between the server and the microcontroller can sniff RS-485 messages and replay previously observed messages. This can be used, for example, to spoof a "quit alarm" message and continuously deactivate the safe alarm.
امتیازهای CVSS
| امتیاز | نسخه | منبع | بردار |
|---|---|---|---|
| 8.6بالا | 4.0 | CVEProject cvelistV5 (CNA) (SEC-VLab) | CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N |
محصولات آسیبپذیر
| فروشنده | محصول | نسخهها | منبع |
|---|---|---|---|
| Wertheim GmbH | Wertheim SafeController 5400 Hardware for VAULT ROOMS (Safe Deposit Locker System - Microcontroller) | Wertheim SafeController 5400, Controller 5400 - AssemblyVersion 6.11.8130.22320 | CVEProject cvelistV5 (CNA) |
منابع و راهنماها
۳
هشدار CVEهای بعدی این محصولمحصول را دنبال کنید تا آسیبپذیریهای تازه را در تلگرام بگیرید.
اطلاعات
- تاریخ انتشار
- ۱۴۰۵/۰۳/۲۵
- آخرین بهروزرسانی
- ۱۴۰۵/۰۳/۲۵
- وضعیت
- منتشرشده
- صادرکننده (CNA)
- SEC-VLab
پیشبینی بهرهبرداری (EPSS)
۰٫۱۹٪
احتمال بهرهبرداری در ۳۰ روز
۹٫۳٪
صدک (نسبت به همهی CVEها)
ارزیابی SSVC (CISA)
- قابل خودکارسازی
- خیر
- وضعیت بهرهبرداری
- اثبات مفهوم
- اثر فنی
- کامل
ضعفها (CWE)
- CWE-294Authentication bypass by capture-replay