جزئیات آسیبپذیری
CVE-2025-52873
Cognex In-Sight seriesCognex In-Sight 7000 seriesCognex In-Sight 8000 seriesCognex In-Sight 9000 seriesCognex In-Sight Explorer
Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource
CVSS 4.0
7.2بالا
شرح رسمی (انگلیسی)
Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSystemConfig functionality to modify relevant device properties (such as network settings), contradicting the security model proposed in the user manual.
امتیازهای CVSS
| امتیاز | نسخه | منبع | بردار |
|---|---|---|---|
| 7.2بالا | 4.0 | CVEProject cvelistV5 (CNA) (icscert) | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N |
| 8.1بالا | 3.1 | CVEProject cvelistV5 (CNA) (icscert) | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H |
محصولات آسیبپذیر
| فروشنده | محصول | نسخهها | منبع |
|---|---|---|---|
| Cognex | In-Sight 2000 series | 5.x ≤ v ≤ 6.5.1 | CVEProject cvelistV5 (CNA) |
| Cognex | In-Sight 7000 series | 5.x ≤ v ≤ 6.5.1 | CVEProject cvelistV5 (CNA) |
| Cognex | In-Sight 8000 series | 5.x ≤ v ≤ 6.5.1 | CVEProject cvelistV5 (CNA) |
| Cognex | In-Sight 9000 series | 5.x ≤ v ≤ 6.5.1 | CVEProject cvelistV5 (CNA) |
| Cognex | In-Sight Explorer | 5.x ≤ v ≤ 6.5.1 | CVEProject cvelistV5 (CNA) |
منابع و راهنماها
۱
هشدار CVEهای بعدی این محصولمحصول را دنبال کنید تا آسیبپذیریهای تازه را در تلگرام بگیرید.
اطلاعات
- تاریخ انتشار
- ۱۴۰۴/۰۶/۲۸
- آخرین بهروزرسانی
- ۱۴۰۴/۰۶/۲۸
- وضعیت
- منتشرشده
- صادرکننده (CNA)
- icscert
پیشبینی بهرهبرداری (EPSS)
۰٫۳۳٪
احتمال بهرهبرداری در ۳۰ روز
۲۶٫۸٪
صدک (نسبت به همهی CVEها)
ارزیابی SSVC (CISA)
- قابل خودکارسازی
- خیر
- وضعیت بهرهبرداری
- ندارد
- اثر فنی
- کامل
ضعفها (CWE)
- CWE-732