جزئیات آسیبپذیری
CVE-2025-23403
Siemens SIMATIC IPC DiagBaseSiemens SIMATIC IPC DiagMonitor
CVSS 4.0
7.3بالا
شرح رسمی (انگلیسی)
A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures.
امتیازهای CVSS
| امتیاز | نسخه | منبع | بردار |
|---|---|---|---|
| 7.3بالا | 4.0 | CVEProject cvelistV5 (CNA) (siemens) | CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| 7.0بالا | 3.1 | CVEProject cvelistV5 (CNA) (siemens) | CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
محصولات آسیبپذیر
| فروشنده | محصول | نسخهها | منبع |
|---|---|---|---|
| Siemens | SIMATIC IPC DiagBase | همه | CVEProject cvelistV5 (CNA) |
| Siemens | SIMATIC IPC DiagMonitor | همه | CVEProject cvelistV5 (CNA) |
منابع و راهنماها
۱
هشدار CVEهای بعدی این محصولمحصول را دنبال کنید تا آسیبپذیریهای تازه را در تلگرام بگیرید.
اطلاعات
- تاریخ انتشار
- ۱۴۰۳/۱۱/۲۳
- آخرین بهروزرسانی
- ۱۴۰۴/۰۱/۱۹
- وضعیت
- منتشرشده
- صادرکننده (CNA)
- siemens
پیشبینی بهرهبرداری (EPSS)
۰٫۱۴٪
احتمال بهرهبرداری در ۳۰ روز
۴٫۱٪
صدک (نسبت به همهی CVEها)
ارزیابی SSVC (CISA)
- قابل خودکارسازی
- خیر
- وضعیت بهرهبرداری
- ندارد
- اثر فنی
- کامل
ضعفها (CWE)
- CWE-732Incorrect Permission Assignment for Critical Resource