CVE-2025-14097

Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX AnalyzersRadiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS AnalyzersRadiometer Medical Aps AQT90 FLEX Analyzers

Remote Code Execution Vulnerability in Radiometer Products

CVSS 3.1
7.2بالا

شرح رسمی (انگلیسی)

A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means. The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency. Required Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution: Customers should ensure the following: • The network is secure, and access follows best practices. Local Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                      Exploit Status: Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.

امتیازهای CVSS

امتیازنسخهمنبعبردار
7.2بالا 3.1 CVEProject cvelistV5 (CNA) (Radiometer) CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

محصولات آسیب‌پذیر

فروشندهمحصولنسخه‌هامنبع
Radiometer Medical Aps ABL800 BASIC and ABL800 FLEX Analyzers Application software versions < 6.20MR2 with Windows 7, Windows XP operating systems CVEProject cvelistV5 (CNA)
Radiometer Medical Aps ABL90 FLEX and ABL90 FLEX PLUS Analyzers Application software versions < 3.5MR11 with Windows 7, Windows XP operating systems CVEProject cvelistV5 (CNA)
Radiometer Medical Aps AQT90 FLEX Analyzers Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems CVEProject cvelistV5 (CNA)

منابع و راهنماها

۱
هشدار CVEهای بعدی این محصولمحصول را دنبال کنید تا آسیب‌پذیری‌های تازه را در تلگرام بگیرید.

اطلاعات

تاریخ انتشار
۱۴۰۴/۰۹/۲۶
آخرین به‌روزرسانی
۱۴۰۴/۰۹/۲۶
وضعیت
منتشرشده
صادرکننده (CNA)
Radiometer

پیش‌بینی بهره‌برداری (EPSS)

۰٫۴۶٪
احتمال بهره‌برداری در ۳۰ روز
۴۰٫۵٪
صدک (نسبت به همه‌ی CVEها)

ارزیابی SSVC (CISA)

قابل خودکارسازی
خیر
وضعیت بهره‌برداری
ندارد
اثر فنی
کامل

ضعف‌ها (CWE)

  • CWE-287
    Improper Authentication