Vulnerability details

CVE-2026-9127

Rockwell Automation Studio 5000 Logix Designer

Studio 5000 Logix Designer® – Multiple Vulnerabilities

CVSS 4.0
7.3High

Official description

A remote code execution security issue exists within Studio 5000 Logix Designer® due to incorrect authorization on a configuration file. This can allow any authenticated user to modify the paths of external tools configured within the application. If exploited, an attacker could alter the configuration to point to a malicious executable, resulting in arbitrary code execution when any user interacts with the external tools functionality.

CVSS scores

ScoreVersionSourceVector
7.3High 4.0 CVEProject cvelistV5 (CNA) (Rockwell) CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H

Affected products

VendorProductVersionsSource
Rockwell Automation Studio 5000 Logix Designer V35.00,34.00,34.01, 33.00,33.02, 32.00-32.04 and older CVEProject cvelistV5 (CNA)

References and advisories

1
Kolun on Telegram @kolunsec Exploited CVEs, key news and a daily digest Alerts for this product's next CVEsFollow the product to get new vulnerabilities on Telegram.

Details

Published
2026-07-14
Last updated
2026-07-14
State
Published
Assigner (CNA)
Rockwell

Exploit prediction (EPSS)

0.15%
Probability of exploitation in 30 days
4.4%
Percentile (among all CVEs)

SSVC assessment (CISA)

Automatable
No
Exploitation
None
Technical impact
Total

Weaknesses (CWE)

  • CWE-863
    Incorrect Authorization