Vulnerability details

CVE-2026-82017

IGEL OS 11IGEL OS 12

IGEL OS 12 / 11 Boot Registry Parameter Injection via Unsigned Configuration Area

CVSS 4.0
8.6High

Official description

IGEL OS 12 before 12.7.6 and IGEL OS 11 before 11.11.150 contain a boot registry parameter injection vulnerability that allows attackers with physical access to execute arbitrary Linux loader parameters by writing to an unencrypted and unsigned configuration area read by the signed bootloader. Attackers can inject malicious kernel command line parameters that execute with boot environment privileges without triggering TPM PCR measurement failures, as the attack does not modify the measured boot code.

CVSS scores

ScoreVersionSourceVector
8.6High 4.0 CVEProject cvelistV5 (CNA) (VulnCheck) CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
7.6High 3.1 CVEProject cvelistV5 (CNA) (VulnCheck) CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Affected products

VendorProductVersionsSource
IGEL IGEL OS 11 11.0.0 ≤ v < 11.11.150 CVEProject cvelistV5 (CNA)
IGEL IGEL OS 12 12.0.0 ≤ v < 12.7.6 CVEProject cvelistV5 (CNA)

References and advisories

5
Kolun on Telegram @kolunsec Exploited CVEs, key news and a daily digest Alerts for this product's next CVEsFollow the product to get new vulnerabilities on Telegram.

Details

Published
2026-08-29
Last updated
2026-10-01
State
Published
Assigner (CNA)
VulnCheck

Exploit prediction (EPSS)

0.21%
Probability of exploitation in 30 days
11.8%
Percentile (among all CVEs)

SSVC assessment (CISA)

Automatable
No
Exploitation
Proof of concept
Technical impact
Total

Weaknesses (CWE)

  • CWE-345
    Insufficient Verification of Data Authenticity