Vulnerability details

CVE-2026-123634

F5 NGINX Open SourceF5 NGINX PlusSiemens Industrial Edge Cloud DeviceSiemens Industrial Edge Device Kit - arm64Siemens Industrial Edge Device Kit - x86-64Siemens Industrial Edge Hub

NGINX resolver vulnerability

CVSS 4.0
9.2Critical

Remedy

Versions not listed as affected in the CVE record:
  • NGINX Plus — version 37.3.0.1 and later
  • NGINX Plus — version 37.0.8.1 and later
  • NGINX Open Source — version 1.31.9 and later
  • NGINX Open Source — version 1.30.7 and later
Remedy in the CVE record (record published by: f5)
Workaround: Avoid using SSI or mirror directives and avoid configuring a proxied server name with variables

Official description

This issue occurs when NGINX Plus or NGINX Open Source is configured as a proxy, the proxied server name includes variables, and a Server Side Includes (SSI) or mirror directive sends a subrequest to a location that resolves the same server name. Under these conditions, a specially crafted HTTP request may cause a use-after-free condition in a worker process. An attacker may also be able to execute code if Address Space Layout Randomization (ASLR) is disabled or the attacker can bypass ASLR. Impact: An attacker could leverage this vulnerability to crash the NGINX worker process, corrupt its memory, or perform remote code execution (RCE) Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.

Related news

CVSS scores

ScoreVersionSourceVector
9.2Critical 4.0 CVEProject cvelistV5 (CNA) (f5) CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
8.1High 3.1 CVEProject cvelistV5 (CNA) (f5) CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

VendorProductVersionsSource
F5 NGINX Open Source 0.6.18 ≤ v CVEProject cvelistV5 (CNA)
F5 NGINX Open Source 1.30.0 ≤ v < 1.30.7 CVEProject cvelistV5 (CNA)
F5 NGINX Open Source 1.31.0 ≤ v < 1.31.9 CVEProject cvelistV5 (CNA)
F5 NGINX Plus 37.0.0 ≤ v < 37.0.8.1 CVEProject cvelistV5 (CNA)
F5 NGINX Plus 37.1.0 ≤ v < 37.3.0.1 CVEProject cvelistV5 (CNA)
F5 NGINX Plus R33 ≤ v CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Cloud Device (IECD) All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Device Kit - arm64 All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Device Kit - x86-64 All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Hub All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Management Cloud All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Management Pro V1 All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Management Pro V2 All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Management Virtual All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Own Device (IEOD) All CVEProject cvelistV5 (CNA)
Siemens Industrial Edge Virtual Device (IEVD) All CVEProject cvelistV5 (CNA)

References and advisories

2
Kolun on Telegram @kolunsec Exploited CVEs, key news and a daily digest Alerts for this product's next CVEsFollow the product to get new vulnerabilities on Telegram.

Details

Published
2026-11-18
Last updated
2026-11-20
State
Published
Assigner (CNA)
f5
Kolun priority
43 · Medium

Exploit prediction (EPSS)

1.51%
Probability of exploitation in 30 days
75%
Percentile (among all CVEs)

SSVC assessment (CISA)

Automatable
No
Exploitation
None
Technical impact
Total

Weaknesses (CWE)

  • CWE-416
    Use After Free